{"id":13723,"date":"2024-03-15T07:46:35","date_gmt":"2024-03-15T07:46:35","guid":{"rendered":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/"},"modified":"2025-08-05T22:34:22","modified_gmt":"2025-08-05T22:34:22","slug":"how-to-use-a-handle-reference-to-a-labview-control","status":"publish","type":"post","link":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/","title":{"rendered":"LabVIEW Control Reference Handle Guide"},"content":{"rendered":"<p>In LabVIEW, a Control Reference is a unique value used to identify and manipulate controls. Here are the general steps for using a Control Reference in LabVIEW:<\/p>\n<ol>\n<li>Get the handle reference for the control: Drag and drop the control onto the Front Panel in the Block Diagram, then right-click on the control and select &#8220;Create&#8221;->&#8221;Control Ref&#8221;, and output the handle to a structure for the control reference handle.<\/li>\n<li>Using control reference handles: In places where controls are needed, control reference handles can be used to manipulate controls. Common operations include retrieving control properties, setting control properties, and registering control callback functions.<\/li>\n<li>To obtain the properties of a control: Use the &#8220;Property Node&#8221; to access the control&#8217;s properties by connecting the control reference handle to the input of the Property Node, selecting the desired property, and then outputting the property value to the appropriate location.<\/li>\n<li>Control properties can be set using the &#8220;Property Node&#8221; in LabVIEW. Simply connect the control reference to the input of the Property Node, choose the desired property to set, and then connect the new property value to the appropriate input terminal.<\/li>\n<li>Register callback function: The &#8220;Register for Events&#8221; node allows you to register a callback function to respond to specific control events. Connect the control reference handle to the input of the Register for Events node, then select the event and callback function to register.<\/li>\n<\/ol>\n<p>It is important to note that control reference handles can only be used in the Block Diagram and within the same window or context as the control. Otherwise, errors may occur.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In LabVIEW, a Control Reference is a unique value used to identify and manipulate controls. Here are the general steps for using a Control Reference in LabVIEW: Get the handle reference for the control: Drag and drop the control onto the Front Panel in the Block Diagram, then right-click on the control and select &#8220;Create&#8221;->&#8221;Control [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_import_markdown_pro_load_document_selector":0,"_import_markdown_pro_submit_text_textarea":"","footnotes":""},"categories":[1],"tags":[18353,18351,13940,18352,3966],"class_list":["post-13723","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-block-diagram","tag-control-reference","tag-front-panel","tag-handle-reference","tag-labview"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.5 (Yoast SEO v21.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>LabVIEW Control Reference Handle Guide - Blog - Silicon Cloud<\/title>\n<meta name=\"description\" content=\"Learn to get and use LabVIEW control reference handles for efficient manipulation. Step-by-step instructions included.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"LabVIEW Control Reference Handle Guide\" \/>\n<meta property=\"og:description\" content=\"Learn to get and use LabVIEW control reference handles for efficient manipulation. Step-by-step instructions included.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog - Silicon Cloud\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/SiliCloudGlobal\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-15T07:46:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-05T22:34:22+00:00\" \/>\n<meta name=\"author\" content=\"Jackson Davis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@SiliCloudGlobal\" \/>\n<meta name=\"twitter:site\" content=\"@SiliCloudGlobal\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jackson Davis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/\"},\"author\":{\"name\":\"Jackson Davis\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/#\/schema\/person\/55a10b8b0457c35884c25677889ad350\"},\"headline\":\"LabVIEW Control Reference Handle Guide\",\"datePublished\":\"2024-03-15T07:46:35+00:00\",\"dateModified\":\"2025-08-05T22:34:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/\"},\"wordCount\":268,\"publisher\":{\"@id\":\"https:\/\/www.silicloud.com\/blog\/#organization\"},\"keywords\":[\"Block Diagram\",\"Control Reference\",\"Front Panel\",\"Handle Reference\",\"LabVIEW\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/\",\"url\":\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/\",\"name\":\"LabVIEW Control Reference Handle Guide - Blog - Silicon Cloud\",\"isPartOf\":{\"@id\":\"https:\/\/www.silicloud.com\/blog\/#website\"},\"datePublished\":\"2024-03-15T07:46:35+00:00\",\"dateModified\":\"2025-08-05T22:34:22+00:00\",\"description\":\"Learn to get and use LabVIEW control reference handles for efficient manipulation. Step-by-step instructions included.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.silicloud.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"LabVIEW Control Reference Handle Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/#website\",\"url\":\"https:\/\/www.silicloud.com\/blog\/\",\"name\":\"Silicon Cloud Blog\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.silicloud.com\/blog\/#organization\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/#organization\",\"name\":\"Silicon Cloud Blog\",\"url\":\"https:\/\/www.silicloud.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.silicloud.com\/blog\/wp-content\/uploads\/2023\/11\/EN-SILICON-Full.png\",\"contentUrl\":\"https:\/\/www.silicloud.com\/blog\/wp-content\/uploads\/2023\/11\/EN-SILICON-Full.png\",\"width\":1024,\"height\":1024,\"caption\":\"Silicon Cloud Blog\"},\"image\":{\"@id\":\"https:\/\/www.silicloud.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/SiliCloudGlobal\/\",\"https:\/\/twitter.com\/SiliCloudGlobal\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/#\/schema\/person\/55a10b8b0457c35884c25677889ad350\",\"name\":\"Jackson Davis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.silicloud.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/2fdb47d6df1226e92380d96973782572a97b0675d098bb914410dec348eb5d29?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/2fdb47d6df1226e92380d96973782572a97b0675d098bb914410dec348eb5d29?s=96&d=mm&r=g\",\"caption\":\"Jackson Davis\"},\"url\":\"https:\/\/www.silicloud.com\/blog\/author\/jacksondavis\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"LabVIEW Control Reference Handle Guide - Blog - Silicon Cloud","description":"Learn to get and use LabVIEW control reference handles for efficient manipulation. Step-by-step instructions included.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/","og_locale":"en_US","og_type":"article","og_title":"LabVIEW Control Reference Handle Guide","og_description":"Learn to get and use LabVIEW control reference handles for efficient manipulation. Step-by-step instructions included.","og_url":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/","og_site_name":"Blog - Silicon Cloud","article_publisher":"https:\/\/www.facebook.com\/SiliCloudGlobal\/","article_published_time":"2024-03-15T07:46:35+00:00","article_modified_time":"2025-08-05T22:34:22+00:00","author":"Jackson Davis","twitter_card":"summary_large_image","twitter_creator":"@SiliCloudGlobal","twitter_site":"@SiliCloudGlobal","twitter_misc":{"Written by":"Jackson Davis","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/#article","isPartOf":{"@id":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/"},"author":{"name":"Jackson Davis","@id":"https:\/\/www.silicloud.com\/blog\/#\/schema\/person\/55a10b8b0457c35884c25677889ad350"},"headline":"LabVIEW Control Reference Handle Guide","datePublished":"2024-03-15T07:46:35+00:00","dateModified":"2025-08-05T22:34:22+00:00","mainEntityOfPage":{"@id":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/"},"wordCount":268,"publisher":{"@id":"https:\/\/www.silicloud.com\/blog\/#organization"},"keywords":["Block Diagram","Control Reference","Front Panel","Handle Reference","LabVIEW"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/","url":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/","name":"LabVIEW Control Reference Handle Guide - Blog - Silicon Cloud","isPartOf":{"@id":"https:\/\/www.silicloud.com\/blog\/#website"},"datePublished":"2024-03-15T07:46:35+00:00","dateModified":"2025-08-05T22:34:22+00:00","description":"Learn to get and use LabVIEW control reference handles for efficient manipulation. Step-by-step instructions included.","breadcrumb":{"@id":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.silicloud.com\/blog\/how-to-use-a-handle-reference-to-a-labview-control\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.silicloud.com\/blog\/"},{"@type":"ListItem","position":2,"name":"LabVIEW Control Reference Handle Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.silicloud.com\/blog\/#website","url":"https:\/\/www.silicloud.com\/blog\/","name":"Silicon Cloud Blog","description":"","publisher":{"@id":"https:\/\/www.silicloud.com\/blog\/#organization"},"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.silicloud.com\/blog\/#organization","name":"Silicon Cloud Blog","url":"https:\/\/www.silicloud.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.silicloud.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.silicloud.com\/blog\/wp-content\/uploads\/2023\/11\/EN-SILICON-Full.png","contentUrl":"https:\/\/www.silicloud.com\/blog\/wp-content\/uploads\/2023\/11\/EN-SILICON-Full.png","width":1024,"height":1024,"caption":"Silicon Cloud Blog"},"image":{"@id":"https:\/\/www.silicloud.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/SiliCloudGlobal\/","https:\/\/twitter.com\/SiliCloudGlobal"]},{"@type":"Person","@id":"https:\/\/www.silicloud.com\/blog\/#\/schema\/person\/55a10b8b0457c35884c25677889ad350","name":"Jackson Davis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.silicloud.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/2fdb47d6df1226e92380d96973782572a97b0675d098bb914410dec348eb5d29?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2fdb47d6df1226e92380d96973782572a97b0675d098bb914410dec348eb5d29?s=96&d=mm&r=g","caption":"Jackson Davis"},"url":"https:\/\/www.silicloud.com\/blog\/author\/jacksondavis\/"}]}},"_links":{"self":[{"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/posts\/13723","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/comments?post=13723"}],"version-history":[{"count":2,"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/posts\/13723\/revisions"}],"predecessor-version":[{"id":157726,"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/posts\/13723\/revisions\/157726"}],"wp:attachment":[{"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/media?parent=13723"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/categories?post=13723"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.silicloud.com\/blog\/wp-json\/wp\/v2\/tags?post=13723"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}